Turnaround time is defined as the usual number of days from the date of pickup of a specimen for testing to when the result is released to the ordering provider. In some cases, additional time should be allowed for additional confirmatory or additional reflex tests. Testing schedules may vary.
D-dimer is one of the protein fragments produced when a blood clot gets dissolved in the body. It is normally undetectable or detectable at a very low level unless the body is forming and breaking down blood clots. Then, its level in the blood can significantly rise. This test detects D-dimer in the blood.
When a blood vessel or tissue is injured and begins to bleed, a process called hemostasis is initiated by the body to create a blood clot to limit and eventually stop the bleeding. This process produces threads of a protein called fibrin, which cross-link together to form a fibrin net. That net, together with platelets, helps hold the forming blood clot in place at the site of the injury until it heals.
Once the area has had time to heal and the clot is no longer needed, the body uses an enzyme called plasmin to break the clot (thrombus) into small pieces so that it can be removed. The fragments of the disintegrating fibrin in the clot are called fibrin degradation products (FDP), which consist of variously sized pieces of crosslinked fibrin.
One of the final FDP produced is D-dimer, which can be measured in a blood sample when present. The level of D-dimer in the blood can significantly rise when there is serious formation and breakdown of fibrin clots in the body.
There are several factors and conditions associated with inappropriate blood clot formation. One of the most common is DVT, which involves clot formation in veins deep within the body, most frequently in the lower legs. These clots may grow very large and block blood flow in the legs, causing swelling, pain, and tissue damage.
It is possible for a piece of the clot to break off and travel to other parts of the body. This “embolus” can lodge in the lungs, causing a PE.
While clots most commonly form in the veins of the legs, they may also form in other areas as well. Measurements of D-dimer can be used to help detect clots in any of these sites. For example, clots in coronary arteries are the cause of myocardial infarction (heart attacks).
Statement on Medical Necessity
All ordered tests should be medically necessary for the diagnosis or detection of disease, illness, impairment, symptom, syndrome, or disorder and the results should be used in the medical management and treatment decisions for the patient. Solaris requires ICD-10 codes with each order for lab testing and both the tests ordered and the diagnosis should be documented in the provider’s medical record for the patient. The United States Department of Health and Human Services, Office of Inspector General, takes the position that a provider who orders medically unnecessary tests may be subject to civil penalties.
Panels and Profiles
Solaris offers Providers the convenience of ordering test combinations in a group at times with the flexibility to choose appropriate test(s) for individual patients. Providers should only order those tests that he or she believes are medically necessary for each patient, and a lesser inclusive profile or individual tests should be ordered if not all tests in the test combination/profile are medically necessary. All tests offered in a test combination/profile may be ordered separately as individual tests. Solaris encourages clients to contact their Solaris representative if the testing configurations shown do not meet individual needs for any reason, or if some other combination of procedures is needed.
CPT Codes
CPT Codes listed are in accordance with Current Procedural Terminology, a publication of the American Medical Association. CPT codes are the responsibility of the billing party and are listed here for informational purposes. Correct coding may vary from one carrier to another. Solaris may bill specific carriers using codes other than what is shown.
For questions or inquiries related to testing please reach out to
customerservice@solarisdx.com or contact us by phone at (844) 550-0308.
Contact Information
Helpful Links